Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
J Endod ; 50(4): 520-526, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38311116

RESUMO

INTRODUCTION: This study aimed to evaluate the effects from the memory-triple (MT) heat treatment on the fatigue resistance of the Reciproc by comparison with the file systems of same geometry. METHODS: Reciproc files subjected to MT heat treatment technology were designated as Group RMT and were compared with the original Reciproc (Group REC) and Reciproc Blue (Group REB). Each NiTi file from 3 groups (n = 15) was operated reciprocally with a repetitive up-and-down movement in the curved canal with 4 mm of pecking distance inside of the simulated canal at body temperature. When each file fractured, the time until fracture was recorded. The length of the fractured fragment was measured. Fractured fragments were observed under scanning electron microscope (SEM) to evaluate the topographic features of the surface. Differential scanning calorimetry (DSC) analysis was performed to estimate phase transformation temperatures. One-way analysis of variance and Duncan post hoc comparison were applied to compare among the groups at a significance level of 95%. RESULTS: RMT showed significantly higher fracture resistance (P < .05), whereas there was no difference in fatigue resistance between REC and REB. SEM examination showed the files from the 3 groups had similar topographic features. RMT showed a peak of austenite peak (Ap) at a temperature (52°C) higher than body temperature, whereas REC and REB showed Ap at 37 and 32°C, respectively. CONCLUSIONS: Under the condition of this study, the new heat treatment technique of MT technology could enhance the fatigue fracture resistance of the reciprocating files made of M-wire and Blue-wire.


Assuntos
Temperatura Alta , Preparo de Canal Radicular , Falha de Equipamento , Estresse Mecânico , Instrumentos Odontológicos , Teste de Materiais , Desenho de Equipamento , Titânio
2.
J Endod ; 49(7): 871-879, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37225037

RESUMO

INTRODUCTION: The aim of this study was to compare the physicochemical properties and biocompatibility of various calcium silicate-based bioceramic sealers (CSBSs). METHODS: Four recently developed CSBSs, including AH Plus Bioceramic Sealer (AHB), EndoSequence BC Sealer (ESB), TotalFill BC Sealer (TTB), and Bio-C Sealer (BIC), were compared with the epoxy resin-based sealer AH Plus (AHP). Their physical properties, including flow, setting time, radiopacity, dimensional stability, and pH, were evaluated according to the International Organization for Standardization (ISO) 6876. Their cytotoxicity in human periodontal ligament fibroblast (hPDLF) was assessed through the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay and compared. Additionally, cell attachment to the sealer surface was analyzed using green fluorescent protein and confocal laser scanning microscopy to evaluate cell viability. Data were analyzed using a one-way analysis of variance to determine the difference between groups for categorical variables, followed by Tukey's post hoc test at the significance level of 95%. RESULTS: The flow, setting time, and radiopacity of all tested CSBSs satisfied the ISO 6876/2012 standards. Further, these CSBSs showed shrinkage after immersion in distilled water for 30 days and complied with the ISO 6876/2001 requirements. The pH values of AHB, ESB, TTB, and BIC were greater than 11, whereas AHP had a pH of 6.69 after 4 weeks. CSBS showed excellent biocompatibility compared with that of AHP (P < .05). Confocal laser scanning microscopy showed that alive hPDLFs were attached well to all the tested CSBSs but not to AHP. CONCLUSIONS: CSBSs have similar physical characteristics within the ISO standards and higher biocompatibility than epoxy resin-based sealers.


Assuntos
Resinas Epóxi , Materiais Restauradores do Canal Radicular , Humanos , Resinas Epóxi/farmacologia , Resinas Epóxi/química , Materiais Restauradores do Canal Radicular/farmacologia , Materiais Restauradores do Canal Radicular/química , Cavidade Pulpar , Teste de Materiais , Compostos de Cálcio/farmacologia , Compostos de Cálcio/química , Silicatos/farmacologia , Silicatos/química
3.
Int Endod J ; 56(7): 792-801, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36942472

RESUMO

This Position Statement on root resorption represents the consensus of an expert committee convened by the European Society of Endodontology (ESE). The statement is based on current clinical and scientific evidence as well as the expertise of the committee. The aim is to provide clinicians with authoritative information on the aetiology, histopathology, clinical presentation and recommendations for the management of root resorption. It is the intention of the committee to update this position statement at appropriate intervals as further evidence emerges.


Assuntos
Endodontia , Reabsorção da Raiz , Humanos , Reabsorção da Raiz/etiologia , Reabsorção da Raiz/terapia , Reabsorção da Raiz/patologia , Consenso
4.
Oral Dis ; 29(7): 2799-2805, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36403223

RESUMO

OBJECTIVES: To describe the association between endodontic treatment failure and medication-related osteonecrosis of the jaw (MRONJ) in a cohort of oncologic patients in therapy with antiresorptive and antiangiogenic drugs. MATERIALS AND METHODS: Patients were selected as affected by MRONJ in absence of the common local risk factors (oral surgical procedures or ill-fitting dentures) but showing failure of previous endodontic treatment performed at least 6 months before the starting of antiresorptive/antiangiogenic therapies. Jaw lesions were all surgically treated and patients underwent a strict clinical and radiological follow-up. RESULTS: Among 18 patients, who developed 18 MRONJ, the only detectable local risk factor was the presence of teeth with failed endodontic treatment (more precisely, root canal underfilling in eight cases, root canal overfilling in two cases, root perforation in three cases, root fracture in five cases). All patients completely healed after surgical procedure and no recurrence was observed. CONCLUSIONS: Endodontic treatment failure should be considered a local risk factor for MRONJ development in oncologic patients. For such reason, it is mandatory to carefully evaluate them prior than the beginning of antiresorptive and antiangiogenic drugs administration.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Conservadores da Densidade Óssea , Humanos , Conservadores da Densidade Óssea/uso terapêutico , Difosfonatos/efeitos adversos , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/diagnóstico por imagem , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/etiologia , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/cirurgia , Fatores de Risco , Assistência Odontológica
5.
Sci Prog ; 105(2): 368504221103763, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35656775

RESUMO

The aim of this study was to explain the mechanical differences between EdgeTaper Platinum (ETP) and ProTaper Gold (PTG) determining the transition temperatures and the composition of the alloy of ETP, since no data are present in literature. A total of 130 instruments were selected: 65 ETP F2 and 65 PTG F2. 20 instruments per type were submitted to each mechanical tests. The cyclic fatigue and torsional tests were performed at a pre-set temperature of 35 °C ± 1 °C. During the cyclic fatigue test, Time to fracture, number of cycles to fracture (NCF) and the fragment length (FL) were recorded. During the static torsional, Torque to Fracture (TtF) and FL were recorded. The fracture surface of 5 randomly selected fragments from each test was examined through a Scanning Electron Microscopy (SEM) and an EDX analysis was performed. 20 instruments per type were submitted to a bending test The force generated (grams) to bend each was recorded. Recorded data of mechanical and metallurgical tests were statistically analyzed using a one-way analysis of variance (ANOVA) test with significance set to a 95% confidence level. ETP F2 showed a higher cyclic fatigue resistance and bending ability than PTG F2, with a statistically significant difference (p < 0.05). PTG showed a higher torsional resistance with a statistically significant difference (p < 0.05). DSC analysis of 5 samples for each instrument type pointed out that the austenite finish temperature of PTG was higher than the ETP, respectively of 49.99 ± 3.31 (°C) and 38.92 ± 1.75 (°C). EDX analysis confirmed the near-equiatomic composition of the Ni-Ti alloys, with a presence of a third component recognized as rubidium in the ETP samples. ETP showed higher flexibility in comparison with PTG, despite the latter is characterized by a more martensitic characterization. since its Af temperature is higher than the ETP.


Assuntos
Endodontia , Temperatura Alta , Metalurgia , Ligas , Endodontia/instrumentação
6.
Pathogens ; 11(6)2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35745508

RESUMO

Background: Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is a viral infection involving multi-organ manifestations. The main oral symptoms of COVID-19 associated are taste loss and xerostomia, but literature has reported other oral manifestation, such as oral blisters, ulcers, vesicles and other immunological lesions. This case report showed an Erythema Multiforme (EM) manifesting as oral mucosa lesions in a patient with a late diagnosis of COVID-19 infection. Case Presentation: A 30 years-old Caucasian woman was sent to an oral medicine office, in order to manage painful and oral mucosa lesions associated with target symmetrical skin lesions. Oral examination revealed extensive ulcers in the mouth and crusts on the lips. Based on clinical examinations, a diagnosis of Erythema Multiforme major was made and a drug therapy with steroids was administered. Five days after the specialist visit, the patient discovered that she was positive for COVID-19. The complete recovery occurred in 3 weeks. Conclusion: Confirming the literature studies, EM is an early disease associated with COVID-19 infection.

7.
Int Endod J ; 55 Suppl 3: 827-842, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35279858

RESUMO

Surgical extrusion, intentional replantation and tooth autotransplantation procedures are important treatment options that clinicians may consider performing in their day-to-day clinical practice. Despite compromised teeth are generally considered for extraction, clinicians must be aware that these cases could be suitable for management by these alternative predictable treatment options. Surgical extrusion, intentional replantation or tooth autotransplantation have similar treatment protocols which includes atraumatic tooth extraction, visualisation of the root portion and replantation. Surgical extrusion is defined as the 'procedure in which the remaining tooth structure is repositioned at a more coronal/supragingival position in the same socket in which the tooth was located originally'. Intentional replantation is defined as the 'deliberate extraction of a tooth and after evaluation of root surfaces, endodontic manipulation and repair, placement of the tooth back into its original position'. Tooth autotransplantation is defined as the 'transplantation of an unerupted or erupted tooth in the same individual, from one site to another extraction site or a new surgically prepared socket'. The same team previously published a narrative review (International Endodontic Journal. 2020, 53, 1636) and European Society of Endodontology position statement (International Endodontic Journal. 2020, 54, 655) on this topic in International Endodontic Journal. The aim of the current updated review was to provide the reader a complete overview and background on these procedures, to established clear clinical protocols and step-by-step for technically perform these therapies in their clinical practice and to establish future directions on the topics. The clinicians must periodically update their knowledge about these three procedures to achieve success.


Assuntos
Endodontia , Reimplante Dentário , Ligamento Periodontal , Tratamento do Canal Radicular , Extração Dentária , Transplante Autólogo
8.
Bioengineering (Basel) ; 8(12)2021 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-34940371

RESUMO

Since the introduction of Nickel-Titanium alloy as the material of choice for the manufacturing of endodontic rotary instruments, the success rate of the root canal therapies has been significantly increased. This success mainly arises from the properties of the Nickel-Titanium alloy: the biocompatibility, the superelasticity and the shape memory effect. Those characteristics have led to a reduction in time of endodontic treatments, a simplification of instrumentation procedures and an increase of predictability and effectiveness of endodontic treatments. Nevertheless, the intracanal separation of Nickel-Titanium rotary instruments is still a major concern of endodontists, with a consequent possible reduction in the outcome rate. As thoroughly demonstrated, the two main causes of intracanal separation of endodontic instruments are the cyclic fatigue and the torsional loads. As results, in order to reduce the percentage of intracanal separation research and manufacturers have been focused on the parameters that directly or indirectly influence mechanical properties of endodontic rotary instruments. This review describes the current state of the art regarding the Nickel-Titanium alloy in endodontics, the mechanical behavior of endodontic rotary instruments and the relative stresses acting on them during intracanal instrumentation, highlighting the limitation of the current literature.

9.
J Imaging ; 7(11)2021 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-34821869

RESUMO

(1) Background: the frequency with which diagnostic tests are prescribed with exposure to ionizing radiation, a cause of biological damage, has been studied, and with much more attention, patients are subjected to these diagnostic tests for diagnosis and follow-up. This review aimed, given the recent developments of this technology, to evaluate the possible use of ultrasound in different branches of dentistry. The possibility of applying ionizing-radiation-free diagnostic exams in dentistry, overcoming the limits of this application, has led scientific research in this area to obtain interesting results that bode well for the future. (2) Methods: a search for articles on the application of ultrasounds in dentistry was performed using the PubMed electronic database. (3) Results: only 32 studies were included, and these clearly stated that this examination is widely usable and in great progress. (4) Conclusions: regarding the modern application techniques of this diagnostic test, it is essential to consider technological evolution as an objective to reduce the damage and side effects of necessary diagnostic tests. The use of ultrasound in dentistry can represent a valid radiation-free alternative, in certain contexts, to the other most used exams.

10.
Materials (Basel) ; 14(21)2021 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-34771850

RESUMO

The aim of this study was to assess the role of the crystallographic phase of Nickel-titanium (NiTi) rotary instruments in determining their torsional resistance during different bending conditions, such as different degrees and angles of curvature. 200 F-One 20.04 instruments (Fanta Dental, Shanghai, China) were used, 100 austenitic instruments and 100 martensitic instruments. Each group was divided in 5 subgroups according to the different bending conditions (straight canal, 90° or 60° of curvature degrees and 3 mm or 5 mm of radius of curvature). The static torsional test was performed by using a device composed of an electric motor capable of recording torque values (N·cm); a vice used to secure the instruments at 3 mm from the tip; and artificial canals, which allow instruments to remain flexed during test. Each instrument was rotated at 500 rpm with a torque limit set to 5.5 Ncm until its fracture. Torque at Fracture (TtF) was registered. A scanning electron microscopy (SEM) observation was conducted. The collected data confirm that an increase in the angle of curvature and a decrease in the radius of curvature of the artificial canals lead to an increase of TtF values with a statistically significant difference (p < 0.05), both in the austenitic and martensitic groups. Regarding the comparison between austenitic and martensitic groups in the same bending condition, a statistically significant difference was found only when the torsional test was performed in the canals with the degrees of curvature of 90° and the radius of curvature of 3 mm and 5 mm, with the austenitic instruments showing a higher TtF than the martensitic ones. In conclusion, it can be stated that the crystallographic phase influences the maximum torque at fracture when the instruments are subjected to severe bending and that the radius of curvature significantly influences their torsional resistance.

11.
J Contemp Dent Pract ; 22(4): 361-364, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34267004

RESUMO

AIM AND OBJECTIVE: The present study aims to evaluate the difference in torsional resistance of two reciprocating nickel-titanium (Ni-Ti) rotary files: WaveOne Gold and EdgeOne Fire. MATERIALS AND METHODS: A total of 40 nickel-titanium rotary instruments (n = 40): 20 WaveOne Gold Small (WOGS) and 20 EdgeOne Fire Small (EOFS) were divided into two groups. Each instrument was tested using a torsional resistance device already validated in previous studies to evaluate and compare torsional resistance. The static torsional test was implemented by blocking each instrument at 3 mm from the tip and rotating it until fracture with a reciprocating motion. Torque to fracture (TtF) and fragment length (FL) were measured and statistically analyzed. RESULTS: Statistical analysis of TtF found significant differences between the two groups (p<0.05). The EOFS showed higher TtF if compared to WOGS, with a mean value and a standard deviation of 3.05 ± 0.07 (N cm) against 2.97 ± 0.08 (N cm). Data for FL showed no significant differences (p>0.05) between the two groups. CONCLUSION: According to the results of this study, it is reasonable to assert that EOFS instruments showed a higher torsional resistance if compared to the WOGS. CLINICAL SIGNIFICANCE: As evidenced by this study, EOFS should be considered as a safer solution, in terms of torsional resistance, if compared to WOGS, reducing the risk of intracanal separation due to excessive torsional load.


Assuntos
Níquel , Titânio , Ligas Dentárias , Instrumentos Odontológicos , Desenho de Equipamento , Temperatura Alta , Teste de Materiais , Preparo de Canal Radicular , Torção Mecânica
12.
J Contemp Dent Pract ; 22(4): 427-434, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34267014

RESUMO

AIM: The aim of this systemic review is to investigate these parameters by analyzing the characteristics of fractured instruments to determine which is the most relevant mechanical stress that induces intracanal separation in vivo. BACKGROUND: The fracture of nickel-titanium (Ni-Ti) instruments is a result of flexural fatigue and torsional fatigue. An electronic search was conducted in MEDLINE database, Web of Science, and Cochrane following preferred reporting items for systematic reviews and meta-analyses guidelines. Data were collected and the key features from the included studies were extracted. Overview quality assessment questionnaire scoring assessed the quality of the articles. A total of 12 articles were selected, where the lowest score was 13. REVIEW RESULTS: Considering Ni-Ti rotary instruments, this overall evaluation comprehends 939 broken instruments with an incidence of fracture of 5%. Out of the 12 selected articles, 10 studies revealed that flexural failure was the predominant mode (range of 62-92%). It appears that motion plays an important role when it comes to mechanisms of fracture. The majority of defects found in hand-operated instruments were in the form of torsional failure. Although the major cause of separation of rotary instruments is flexural fatigue, smaller instruments show more torsional fracture than the larger instruments. The average fragment length was found to be 2.5 mm and 3.35 mm, respectively, for torsional failure and flexural failure. The risk of bias depends on fractographic analysis. CONCLUSION: Flexural fatigue is the predominant mode of fracture in rotary Ni-Ti instruments. The type of motion and size of the instrument seem to affect the mechanism of fracture. Fragment length may show a strong association with the type of fracture mechanism. CLINICAL SIGNIFICANCE: This systemic review found that flexural fatigue is the most relevant mechanical stress that induces intracanal separation in vivo. Moreover, in clinical practice, the fragment length might be an excellent indicator of the type of fracture.


Assuntos
Níquel , Titânio , Ligas Dentárias , Instrumentos Odontológicos , Desenho de Equipamento , Falha de Equipamento , Incidência , Preparo de Canal Radicular , Estresse Mecânico , Torção Mecânica
13.
Diagnostics (Basel) ; 11(6)2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34205946

RESUMO

AIM: To assess the potential ability of nuclear magnetic resonance micro-imaging (mMRI) to visualize and identify soft tissue debris and unfilled spaces inside radicular canals in endodontic treated extracted teeth, for understanding the causes of treatment failure. Toward this goal, multi-parametric mMRI and cone beam computed tomography (CBCT) were compared. METHODOLOGY: A non-recoverable root treated human tooth was extracted due to endodontic failure and excessive mobility. It was examined with both CBCT and mMRI: CBCT was performed with 0.125 mm voxel size (GXCB-500, Kavo-Gendex, Brea, CA, USA) and mMRI was performed with a spectrometer operating at 9.4T magnetic field (Bruker Avance-400, Bruker, Billerica, MA, USA). The mMRI images were obtained with a microimaging probe. Relaxation times (T1 and T2) and diffusion-weighted acquisition sequences were used to obtain multi-parametric maps of the extracted tooth (slice thickness of 200 µm and in plane resolution of 30 × 30 µm2). RESULTS: T1 and T2 maps identified unfilled spaces around and close to Gutta-percha cones instead of CBCT images that were not able to highlight this aspect. T1, T2 and apparent diffusion coefficient (ADC) assumed different values in dentine and in voids, characterized by different dimensions. Moreover, they were able to discriminate between infiltrations of water only and deposits of biological material. Because Gutta-percha cones are constituted of hard, non-porous material, they do not provide a signal and in mMRI images appear as zones of noise. CONCLUSIONS: Unlike the CBCT exam, mMRI can detect soft tissue debris and unfilled spaces inside radicular canals. Therefore, this in vitro study showed the potential of mMRI to evaluate the quality of the root canal treatment, suggesting its potential benefit in determining the causes of endodontic failure, without the use of ionizing radiation.

14.
J Contemp Dent Pract ; 22(3): 215-218, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34210917

RESUMO

AIM AND OBJECTIVE: The aim and objective of this study was to evaluate and compare the cutting efficacy of two different nickel titanium rotary instruments by a novel methodology: the operative torque (torque and time needed to progress toward the apex). MATERIALS AND METHODS: Ten fresh extracted upper first premolars with two canals were instrumented with a KaVo (Biberach, Germany) and a KaVo 1:1 handpiece at 300 rpm with maximum torque set at 2 N. One canal was instrumented with ProGlider NiTi rotary instruments (Dentsply Sirona Endodontics, Ballaigues, Switzerland), with tip size of 16.02, and the other one with EgdeGlidePath rotary instrument (EdgeEndo, Albuquerque, New Mexico). Mean instrumentation time, mean torque values, and maximum torque values were evaluated for each instrument. The significance level was set at p <0.05. RESULTS: EdgeGlidePath instruments reached the working length in significantly less time with a significantly smaller amount of torque when compared to ProGlider (p >0.05). No instruments exhibited flute deformation or underwent intracanal failure. CONCLUSIONS: Operative torque is related to the capability to cut dentin and progress toward the apex: the smaller the torque values, the higher the cutting ability (and safety). Operative torque is also dependent on debris removal and irrigation techniques. Nevertheless, both operative torque and instrumentation time are clinically relevant parameters for evaluating instruments' performance (i.e., cutting ability). CLINICAL SIGNIFICANCE: Operative torque during endodontic instrumentation helps understanding the overall performance in terms of both cutting efficiency and safety.


Assuntos
Níquel , Preparo de Canal Radicular , Ligas , Ligas Dentárias , Instrumentos Odontológicos , Cavidade Pulpar , Desenho de Equipamento , Alemanha , Titânio , Torque
15.
Materials (Basel) ; 14(13)2021 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-34279315

RESUMO

Previously published studies have investigated the influence of instrument access on cyclic fatigue resistance. However, no studies have evaluated the relationship between angulated access and torsional resistance. The aim of this study was to investigate the influence of the angle of access on the torsional resistance of endodontic instruments. One hundred and eighty instruments were selected: 90 F-One Blue 25/04 and 90 HeroShaper 25/04 instruments. Three subgroups (n = 30) for each instrument type (A and B) were established according to the angle of insertion of the instruments inside the artificial canal (0°, 10° and 20°). The tests were performed using a custom-made device consisting of the following: a motor that can record torque values of 0.1 s; interchangeable stainless-steel canals with different curvature (0°, 10° and 20°) that allow the instrument's angulated insertion and keep it flexed during testing procedures; and a vise used to secure the instrument at 3 mm from the tip. Torque limit was set to 5.5 Ncm, and each instrument was rotated at 500 rpm until fracture occurred. Torque to fracture (TtF) was registered by the endodontic motor, and the fragment length (FL) was measured with a digital caliper. Fractographic analysis was performed using a scanning electron microscopy (SEM) evaluation to confirm the cause of failure. TtF values and fragment length (FL) values were statistically analyzed using one-way analysis of variance (ANOVA) test and the Bonferroni correction for multiple comparisons across the groups with significance set to a 95% confidence level. Regarding the F-One Blue instruments, the results showed a higher TtF for group A3 (20°) than for group A1 (0°) and group A2 (10°), with a statistically significant difference between group A3 and the other two groups (p < 0.05), whereas no statistically significant difference was found between group A1 and group A2 (p > 0.05). Regarding the HeroShaper instrument, the results showed the highest TtF for group B3, with a statistically significant difference between the three subgroups B1, B2 and B3 (p < 0.05). The results showed that the torsional resistance increases as the angle of instrument access increases with a varying intensity, according to the crystallographic phase of the instrument selected.

16.
Dent Res J (Isfahan) ; 18: 34, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34322210

RESUMO

The aim of the present study was to describe two clinical cases showing postoperative pain associated with the use of plastic carrier obturation system and apical bone fenestration. The patients were treated by surgical access and apicoectomy through a modern technique (using magnification and microsurgical approach), thus removing the direct contact between obturation material and submucosal connective tissue. The surgical interventions were carried on without the occurrence of any complication. Postsurgical adverse sequelae were negligible. After few weeks from the surgery, all symptoms disappeared. Radiographic healing was observed after 48 months. The presence of apical bone fenestration could be the cause of persistent pain after root canal treatment. The contact between plastic carrier and submucosal connective tissue could be the direct cause of spontaneous pain even in absence of periapical infection. Since the clinical diagnosis could be difficult, the use of tridimensional radiology could be justified. Surgical approach, by the removal of the contact between the carrier and connective tissues, can be considered a viable option to treat these particular affections.

17.
J Endod ; 47(7): 1149-1156, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33915175

RESUMO

INTRODUCTION: The aim of this study was to investigate the influence of mass and the polar moment of inertia on the torsional behavior of nickel-titanium rotary instruments to understand which parameter of cross-sectional design had a key role in terms of torsional resistance. METHODS: Four different instrument models were designed and meshed using computer-aided engineering software (SolidWorks; Dassault Systems, Waltham, MA). Instrument models shared the same characteristics, except for cross-sectional design; triangle, rectangle, square, and hollow square geometry was selected. Finite element analysis was performed simulating a static torsional test using the FEEPlus internal solver (Solid Works). Von Mises stress and torsional load at fracture were calculated by the software. Linear regression analysis was performed to investigate the relationship of the polar moment of inertia, cross-sectional area, inner core radius, and mass per volume on the torsional resistance of nickel-titanium rotary instruments. RESULTS: The polar moment of inertia positively affected the maximum torsional load with the highest level of correlation (R2 = 0.917). It could be stated that the higher the polar moment of inertia is, the more maximum torsional load at fracture is present. Mass and cross-sectional area had a lower level of correlation compared with the polar moment of inertia (R2 = 0.5533). According to this, 2 instruments with the same mass/mm and/or cross-sectional area could have different torsional resistance. CONCLUSIONS: The polar moment of inertia can be considered as the most important cross-sectional factor in determining the torsional resistance of rotary instruments over metal mass and cross-sectional area.


Assuntos
Níquel , Titânio , Ligas Dentárias , Desenho de Equipamento , Análise de Elementos Finitos , Teste de Materiais , Preparo de Canal Radicular , Estresse Mecânico , Torção Mecânica
18.
Odontology ; 109(3): 568-573, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33245455

RESUMO

Torsional stresses are one of the most frequent causes of intracanal separation of nickel-titanium endodontic instruments, which represents a great concern of endodontists. For this reason, torsional resistance of rotary instruments has been deeply investigated by determining all parameters that can influenced it, that can be summarized in: (1) Tooth-related factors, (2) Strategy-related factors and (3) Instrument-related factors. This study was conducted to examine the influence of shaft length on torsional resistance of a nickel-titanium rotary instrument and if it should be considered as an Instrument-related factor. With this aim, 120 Twisted Files Adaptive M-L (TFA M-L) NiTi instruments (SybronEndo, Orange, CA, USA) were divided into 6 experimental groups (n = 20), according to instruments length and size: Group 1, 20 TFA M-L1 25/08 23 mm; Group 2, 20 TFA M-L1 25/08 27 mm; Group 3, 20 TFA M-L2 35/06 23 mm; Group 4, 20 TFA M-L2 35/06 27 mm; Group 5, 20 TFA M-L3 50/04 23 mm; and Group 6, 20 TFA M-L3 50/04 27 mm. All instruments were submitted to a static torsional test, blocking each instrument at 3 mm from the tip and rotating it until its fracture. Torque to Fracture (TtF) and fragments length were registered and all data were statistically analyzed. Results showed that Groups 2, 4 and 6 had a higher TtF, respectively, than Groups 1, 3 and 5, which differ from the former just for shaft length. Group 6 showed the highest torsional resistance (1.31 ± 0.08 Ncm), whilst Group 1 the lowest (0.40 ± 0.08 Ncm). According to that, it can be stated that the longer the instrument, the higher the torsional resistance is, proving that shaft length should be considered as an important factor about torsional resistance.


Assuntos
Níquel , Titânio , Ligas Dentárias , Instrumentos Odontológicos , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Preparo de Canal Radicular , Estresse Mecânico , Torque , Torção Mecânica
19.
J Endod ; 47(3): 472-476, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33096192

RESUMO

INTRODUCTION: Previously published studies have deeply investigated the characteristics of flexural and torsional resistance of nickel-titanium rotary instruments, but none of them investigated the relationship between the 2 stresses. The objective of the present study was to evaluate the influence of flexural stresses over torsional resistance. METHODS: Sixty S-One 20.04 files (Fanta Dental, Shanghai, China) were used in the present study (N = 60) and divided into 3 test groups of 20 files. A customized device made of a mobile structure with a connection that holds the handpiece and the artificial canal was used for the experiment to make the measurements repeatable. The artificial canals were created with a 90° curvature, a 60° curvature, and lastly a straight canal. Each file was rotated at 300 rpm with a maximum torque value of 5.5 Ncm with the apical 2 mm firmly secured in a vise. The torque at fracture and the time to fracture were recorded by the software integrated in the handpiece and evaluated through statistical analysis. RESULTS: Statistical analysis found significant differences in the values of torque to fracture (TtF) between these 3 groups (P < .05). The 90° curved canal group showed the highest TtF value, and the 60° curved canal group showed a higher TtF value than the straight canal group. CONCLUSIONS: The results of the present study demonstrated a positive influence of flexural stresses over torque at fracture of rotary files. When nickel-titanium instruments were used in a 90° or 60° curvature, the values of torque at fracture increased compared with the same instruments that rotated in the straight canal.


Assuntos
Níquel , Titânio , China , Ligas Dentárias , Instrumentos Odontológicos , Desenho de Equipamento , Falha de Equipamento , Preparo de Canal Radicular , Torque , Torção Mecânica
20.
Aust Endod J ; 47(2): 358-364, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33159493

RESUMO

Retrograde peri-implantitis is a symptomatic complication, characterised by radiographic detection of bone loss at the periapex of the implant. The aim of this study was to investigate the possible endodontic aetiology, evaluating the effectiveness of surgical treatment without endodontic therapy of adjacent teeth. In the 10-year interval, three patients reported symptoms of retrograde peri-implantitis after a mean period of 30.6 days from implant placement. Mean follow-up after surgical procedures was 8.66 years, with an implant survival of 100%. Retrograde peri-implantitis was probably caused by colonisation of the apical surface of the implant by bacteria persisting in the area after endodontic failure/apical periodontitis, reactivated by drilling in the site. In all cases, the adjacent teeth remained vital during the years, showing that a direct cause-and-effect relationship between pulpal/periapical disease of adjacent teeth and retrograde peri-implantitis was never present.


Assuntos
Implantes Dentários , Doenças da Polpa Dentária , Peri-Implantite , Periodontite Periapical , Polpa Dentária , Humanos , Peri-Implantite/diagnóstico por imagem , Peri-Implantite/etiologia , Periodontite Periapical/diagnóstico por imagem , Periodontite Periapical/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...